D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co

  • Audited Supplier
  • 10 yrs

Contact Supplier

Product Highlights

  • ATEX SIL2 Certified: Certified for hazardous areas with Ex d IIC T6 GB and SIL2 safety integrity level.
  • Fast Response Time: Response time T90 is less than or equal to 30 seconds for toxic gases.
  • Versatile Signal Output: Supports 4-20mA and RS485 signals with 3-wire or 4-wire wiring options.
  • Durable Aluminum Body: Constructed from ADC12 Aluminum with a compact size of 145*148*92mm.
  • Free Technical Training: Complimentary technical training included with the after-sales service package.
  • 1-Year Warranty: Comprehensive 1-year warranty coverage for peace of mind and reliability.
  • Real-Time Monitoring: Fixed installation for continuous real-time monitoring of combustible and toxic gases.

Product Images of D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co

D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co pictures & photos
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co pictures & photos
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co pictures & photos
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co pictures & photos
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co pictures & photos
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co pictures & photos
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
  • D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
  • D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
    D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
  • D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
    D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
  • D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
    D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
  • D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
    D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
  • D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
    D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
  • D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
    D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co

Find Similar Products

Product Description


Detection of the leakage of flammable and toxic gasses used in petroleum and chemical engineering. The ATEX SIL2 certified Gas Leakage Detector with English Menu is fixed in areas such as workshops, warehouses and storage tanks for real-time monitoring of the concentration of flammable and toxic gasses. 
Detailed Photos
 
 
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s CoD6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s CoD6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
Product Description

 

Model GTQ-D6000A GTQ-D6000S D6600A D6600S
Gas Detected Ex Ex Toxic Toxic
Response Time T90≤30S T90≤30S T90≤60S/180S T90≤60S/180S
Accuracy  ≤±5%FS ≤±5%FS ≤±5%FS ≤±5%FS
Repeatability ≤2%FS ≤2%FS ≤2%FS ≤2%FS
Signal Output 4-20mA RS485 4-20mA RS485
Wiring  three-wire four-wire three-wire four-wire
Relay Output 2 passive relays 2 passive relays 2 passive relays 2 passive relays
 
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co
D6000 Series Fixed Gas Detector for Combustible and Toxic Gas O2 H2s Co

About the Supplier

Watch Video
Watch Video
Nanjing AIYI Technologies Co., Ltd.
Nanjing AIYI Technologies Co., Ltd.
Nanjing AIYI Technologies Co., Ltd.
Nanjing AIYI Technologies Co., Ltd.
Nanjing AIYI Technologies Co., Ltd.
Nanjing AIYI Technologies Co., Ltd.
Nanjing AIYI Technologies Co., Ltd.
Nanjing AIYI Technologies Co., Ltd.

About Our Factory & Business Background

Address
Building 12, No. 3118 Jiyin Avenue, Jiangning District, Nanjing, Jiangsu, China
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main Products
Gas Detector, Portable Gas Detector, Gas Monitor, Fixed Gas Detector, Gas Detection System, Gas Analyzer, China Gas Detector, Gas Sensor, Dust Monitor, Gas Meter

Our Industry Experience & Global Business Record

Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What certifications does the D6000 Series have?
The detector is certified with CE, RoHS, ATEX (Ex d IIC T6 GB), and SIL2.
What is the response time for gas detection?
The response time T90 is less than or equal to 30 seconds for toxic gas models.
What signal outputs are supported?
It supports 4-20mA and RS485 signals, with options for 3-wire or 4-wire wiring.
Is the product customizable?
Yes, the product is customized, including explosion-proof ratings and dimensions.
What is the warranty period?
We provide a 1-year warranty for the D6000 Series fixed gas detector.
What after-sales services are included?
Free technical training is provided as part of the after-sales service.
What is the lead time for orders?
The average lead time is within 15 workdays for both peak and off-season.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now